Name | Yankauer Suction Tube – Pediatric |
Lead Time | 0-3 days |
Competitor | ;VM216316;VM21-6316;170118;170-118;098504;09-8504;22-6585;226585;0985-04; |
Specialty | General Instruments-Suction Tubes, Needles & Probes – Suction Tubes |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Medicrest Surgical Industries |
Sterility | Non-Sterile |
Usage | Reusable |
Yankauer Suction Tube – Pediatric
Suction Tube
small pattern, narrow handle (pediatric), w/ removable tip, 8-1/4″ (21.0 cm) overall length
Yankauer Suction Tube is designed to be used during general procedures involving pediatrics due to the narrow handle and smaller pattern. The reason of using this tube is to clean the surgical site, thereby also removing debris or fluids and reducing the chance for infection. The end of the tube contains a removable bulb-shaped tip, and the overall length is 8 ¼.”
SKU: MSI-01-879
Category: Suction Tubes, Needles & Probes
Description
Reviews (0)
Be the first to review “Yankauer Suction Tube – Pediatric” Cancel reply
Related products
Suction Tube
Suction Tube
w/ removable tip
Yankauer Suction Tube comes with a tip that can be removeved to allow access to tighter spaces. If these tips get lost, however, they can be purchased separately to be used only for the Yankauer suction tube. This device is also long in length and can range from 10 ¼" to 18" depending on the operation. The handle of this device contains an end that can be connected to a suction source in order to provide the suction power needed to remove fluids or debris away from the surgical site.
Grooved Director & Tongue Tie – Probe Point
Grooved Director & Tongue Tie - Probe Point
stainless steel, probe point
Grooved Director and Tongue Tie is a stainless steel instrument that contains a probe point on one end typically used to examine the mouth in young children. The other end consists of a flat butterfly-shaped end. In frenotomy procedures that require stabilizing the tongue, the grooved director can assist in this process and provide a better view for the surgeon. Different sizes are available to accommodate different cases.
Frazier Suction Tube
Frazier Suction Tube
angled, w/ finger cut-off, 4" (10.2 cm) working length
Frazier Suction Tube has an angled tube and is available in a variety of different sizes and widths depending on the operation. This tube has a finger cut-off on a 4" working length and performs similar to a pump with a suction force. The purpose of this suction force is to be used in general operations in which materials or fluid, typically blood, need to be removed to provide a cleaner working area.
Frazier Suction Tube Stylet
Frazier Suction Tube Stylet
Frazier Suction Tube Stylet is a thin wire device that serves the purpose of clearing any contents that remain inside the Frazier Suction Tube. All of the sizes offered of this stylet are specifically designed to enter each of the various sizes and thickness of the Angled Frazier Suction Tube with finger cut-off and 4" working length.
Cooley Graft Suction Tube
Cooley Graft Suction Tube
8.0 mm wide round perforated tip, 7" (17.8 cm) working length, 12" (30.5 cm) overall length
Cooley Graft Suction Tube is a popular instrument used in various surgical operations to eliminate and clear bodily fluids that may obstruct the view of the surgical site. For this reason, the distal end of the tube contains a piece that is attached to a suction machine in order to provide the suction power for the instrument to perform. The other end contains a long tube that has an 8.0 mm wide tip, which allows it to extract greater amount of fluid away from the area.
Coakley Antrum Trocars
Coakley Antrum Trocars
w/ cannula & irrigating extension, strong curve, 6-1/4" (15.9 cm)
Coakley Antrum Trocars serves the purpose of withdrawing fluid from a part of the body, such as the sinuses. A cannula and irrigating extension are offered with the trocars to further assist the process. This instrument is protected by the Surgical manufacturer warranty on defects in materials and workmanship.
Adson Suction Tube
Adson Suction Tube
w/ finger cut-off, curved
Adson Suction Tube contains a finger cut-off valve to place rest the finger on and a grip handle for a better hold. This instrument is available in several different French measurements on a 5" or 8" working length. The intended purpose of this suction tube with a slightly curved tip is to remove any excess liquids or fluids that are present on the surgical site. In this way, the surgeon may have a clear view of the area being operated.
Tongue Tie – Plain Point
Tongue Tie - Plain Point
stainless steel, plain point
Grooved Director and Tongue Tie contains a plain point at one end and a butterfly-shaped director on the other end. This stainless steel instrument is typically used during a frenotomy to lift the tongue back and expose the frenulum. The frenulum would rest on the grooved part of the director and then be cut with iris scissors. Depending on the patient, this device is offered in various lengths.