Name | Probe W/ Eye |
Lead Time | Lead time advised within 48 hours of order placement. |
Competitor | ;180200;180-200;494030;49-4030;0910-11;180201;180-201;091213;09-1213;494031;49-4031;0910-13;BD034R;BN034R;180202;180-202;30789;091214;09-1214;0910-14;BN036R;180203;180-203;091215;09-1215;49-4033;494033;0910-15;180204;180-204;0910-18;BN040R;180205;180-205;091220;09-1220;494035;49-4035;0910-20;180207;180-207;180238;180-238;494037;49-4037;0910-25;0910-11_0910-25; |
Specialty | General Instruments-Suction Tubes, Needles & Probes – Probes |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Medicrest Surgical Industries |
Sterility | Non-Sterile |
Usage | Reusable |
Probe W/ Eye
Probe W/ Eye
stainless steel
Probe is a slender stainless steel device that ranges from 4 ½” to 10″ in total length and contains an eye opening on one end. The popularity of this probe arises in its ability to explore lesions or body cavities to display the underlying tissues that need to be examined.
SKU: MSI-01-872
Category: Suction Tubes, Needles & Probes
Description
Reviews (0)
Be the first to review “Probe W/ Eye” Cancel reply
Related products
Frazier Suction Tube – Semi-Rigid W/ Slot
Frazier Suction Tube - Semi-Rigid W/ Slot
angled, semi-rigid w/ slot, 5-1/2" (14.0 cm) working length
Frazier Suction Tube is semi-rigid with a slot on the handle. The tube is angled and is primarily utilized during general surgeries to remove any fluids or blood that may occupy the surgical site obstructing the surgeon's view. In this case, the thin diameter of the tube, in addition to the 5 ½" length, is able to enter small areas that require matter to be eliminated.
Suction Tube
Suction Tube
w/ removable tip
Yankauer Suction Tube comes with a tip that can be removeved to allow access to tighter spaces. If these tips get lost, however, they can be purchased separately to be used only for the Yankauer suction tube. This device is also long in length and can range from 10 ¼" to 18" depending on the operation. The handle of this device contains an end that can be connected to a suction source in order to provide the suction power needed to remove fluids or debris away from the surgical site.
Grooved Director & Tongue Tie – Probe Point
Grooved Director & Tongue Tie - Probe Point
stainless steel, probe point
Grooved Director and Tongue Tie is a stainless steel instrument that contains a probe point on one end typically used to examine the mouth in young children. The other end consists of a flat butterfly-shaped end. In frenotomy procedures that require stabilizing the tongue, the grooved director can assist in this process and provide a better view for the surgeon. Different sizes are available to accommodate different cases.
Vein Stripper
Vein Stripper
complete set in stainless steel sterilizing case, includes: traction cable, handle, plastic probe tip, metal probe tip, olive adaptors (6.0 mm, 9.0 mm & 12.0 mm)
Nabatoff Vein Stripper is a complete set loaded in a stainless steel sterilizing case that includes several tools such as traction cable, handle, probe tips, and olive adaptors. This instrument is typically used during procedures that involve the removal of varicose veins. Once an incision is made around the area, the wire is inserted into the vein and tied so that the vein can be pulled out.
Mayo Vein Stripper
Mayo Vein Stripper
15-3/8" (39.0 cm)
Mayo Vein Stripper is 15 3/8" long instrument with a short grip handle and a long rod with a circular jaw. This vein stripper is typically used in procedures that require the removal of varicose veins because the use of this instrument is quicker and there are fewer infections that appear on the patient. Multiple inner diameters of the ring are available according to the type of vein that needs to be stripped.
Gallbladder Trocar
Gallbladder Trocar
6" (15.2 cm)
Ochsner Gallbladder Trocar is a 6" long instrument and is available in various French circumferences. With the help of a sharp point, the main purpose of this trocar is to drain a fluid-filled cavity. For example, if any pus or mucus resides in the gallbladder, this instrument is able to withdraw that liquid.
Frazier Suction Tube – Extra-Long
Frazier Suction Tube - Extra-Long
extra-long, angled, w/ finger cut-off, 7-1/8" (18.1 cm) working length
Frazier Suction Tube is an extra-long style consisting of a 7 1/8" working length. The handle contains a finger cut-off to rest the finger on, and the tube is angled near the base. The intended purpose of this instrument is to eliminate the operating area of any fluids or substances that may be present so that the surgeon is provided with a clear view. Thus, the suction tube may be used for general surgeries and even gynecological procedures.
Suction Tube
Suction Tube
offset suction tip holes, 3" (7.5 cm) working length
Brackman Suction Tube contains a thumb plate on the handle to rest the finger on and also to control the bypass hole. The tube itself is either 5 or 7 French and has offset suction tip holes. These fine suction tips are designed to be used in surgeries, such as myringoplasty, for areas that are narrow or more delicate in order to avoid excess suction.
Reviews
There are no reviews yet.