Name | McIntyre Lacrimal Probe Cannula |
Lead Time | Lead time advised within 48 hours of order placement. |
Competitor | ;OP0903001;OP0903-001;E43953;E4395-3;601208;60-1208;E-4395-3;6012-08;OP0903002;OP0903-002;601209;60-1209;6012-09;6012-08_6012-09; |
Specialty | Ophthalmology-Cannulas |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Medicrest Surgical Industries |
Sterility | Non-Sterile |
Usage | Reusable |
McIntyre Lacrimal Probe Cannula
2″ (5.0 cm), 23-gauge McIntyre Lacrimal Probe Cannula is an extremely useful tool in treating tear duct obstructions. The probe may be used to investigate blockage of lacrimal gland damage or more frequently, obstruction of the nasolacrimal duct. The slender profile of the cannula allows access to the small entrances of the duct. Both straight and curved models are available depending on surgical preference.
SKU: MSI-05-1063
Category: Cannulas
Description
Reviews (0)
Be the first to review “McIntyre Lacrimal Probe Cannula” Cancel reply
Related products
Kratz Capsule Scraper
shaft w/ sharp top, shaft angled 60 degrees, 12.0 mm tip from angle to tip, 22-gauge, 1/2" Kratz Capusle Scraper is a useful tool in phacoemulsification procedures. The sandblasted tip is designed to scrape the surface of the posterior capsule to remove and cellular debris following aspiration of the nucleus.
Gill-Welsh Olive Tip Cannula
angled 45 degrees, 25-gauge Gills-Welsh Olive Tip Cannula is a commonly used tool in a variety of cataract procedures. The cannula is used to gently manipulate the lens tissue while aspirating remaining debris following phacoemulsification. The 45 degree angled shaft aids in visualization during the procedure.
Knolle Anterior Chamber Irrigating Cannula
irrigating ports at 12, 10 & 2 o'clock, 23-gauge, overall length tip to hub 1-1/2" (3.8 cm) Knolle Anterior Chamber Cannula is a frequently used tool in cataract extraction procedures. The small gauge cannula with angled tip is nimble enough to fit into a small limbal incision accessing the anterior chamber. It may be used to aspirate fluid within the anterior chamber exposing the lens capsule.
McIntyre-Binkhorst Irrigating Cannula
smooth blunt tip, front opening, 26-gauge McIntyre-Binkhorst Irrigating Cannula is a useful tool in cataract procedures. The curved tip of the cannula is used for loosing the peripheral cortex of the lens during difficult extraction. The cannula features a smaller gauge for easier access and a shorter working length for more control. Both right and left curvatures of the cannula are also available depending on surgical preference.
Kratz Cystotome
30-gauge Kratz Cystotome is a commonly used tool during cataract phacoemulsification procedures. The cystotome may be used to create a circular incision in the anterior capsule before proceeding with aspiration of the lens. The sharp tip combined with 60 degree angled shaft allows for easy cutting and visualization.
Randolph Cyclodialysis Cannula
front air injection port, 12.0 mm angled tip, 19-gauge Randolph Cyclodialysis Cannula is a commonly used tool in glaucoma procedures. The cannula is frequently used to irrigate the anterior chamber once a communication has been established between the anterior chamber and the suprachoroidial space. The cannula has a front injection air port and features a flat tip or thin spatula blade depending on surgical preference.
McIntyre Anterior Chamber Cannula
McIntyre Anterior Chamber Cannula is a frequently used tool in cataract IOL implantation procedures. Following nucleus fragmentation, the cannula may be used to aspirate any remaining debris from the anterior chamber. Both angled and straight tips are available in three different gauges depending on surgical preference.
Scheie Anterior Chamber Cannula
blunt, 27-gauge, 3/4" (2.0 cm)Scheie Anterior Chamber Cannula is a frequently used tool in cataract extraction procedures. The small gauge cannula is nimble enough to fit into a small limbal incision accessing the anterior chamber. It may be used to aspirate fluid within the anterior chamber exposing the lens capsule.
Reviews
There are no reviews yet.