Name | Cooley Aortic Aneurysm Clamp |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Medicrest Surgical Industries |
Sterility | Non-Sterile |
Usage | Reusable |
Cooley Aortic Aneurysm Clamp
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4″ (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
SKU: MSI-04-1017
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Cooley Aortic Aneurysm Clamp” Cancel reply
Related products
Cooley Miniature Multi Purpose Clamp
Cooley Miniature Multi Purpose Clamp
jaws calibrated at 5.0 mm intervals.
Cooley Miniature Multi Purpose Clamp is well suited for a variety of uses in cardiothoracic surgical procedures. Although this instrument does not have one particularly function but instead is a multi purpose clamp that can be used in a variety of different instances. The miniature size of this clamp makes it more able to reach certain vessels but also makes it better suited for use in smaller patients. This clamp comes equipped with jaws calibrated at 5 mm intervals and is available in three different angles 30, 60 and 90 degrees.
Cooley Iliac Clamp
Cooley Iliac Clamp
Cooley Iliac Clamp allows for exquisite control of blood flow through large arteries during a number of orthopedic and cardiac procedures, or whenever temporary occlusion of the iliac vasculature is desired. Renowned for its ease of use, Cooley Iliac Clamp is designed for the application of variable pressures on the Iliac artery to prevent intrusive blood flow. It provides for a strong, secure and adjustable grip which can be used for closure of vasculature or secure clamping of soft tissue. The jaws are set at a slight angle so as to allow maneuverability while still maintaining pressure and control when clamping the intended area. This clamp features straight jaws, handles angled at 45 degrees and is available in two different jaws sizes.
Exclusion Clamp
Exclusion Clamp
s shaped, curved jaws 8.5 cm, 7-1/4" (18.5 cm)
Aortic Exclusion Clamp are ideally made for use in cardiothoracic surgical procedures in which there is a need to exclude a certain portion of the aorta. The unique "S" shaped curvature of the jaws makes it contoured to fit the unique curvature and shapes necessary of atraumatic clamping of vessels. Although this instrument could have a wide application on other vessels it is designed for use in clamping of the aorta. This instrument is comprised of premium German operating-room grade stainless steel.
Cooley Renal Artery Clamp
Cooley Renal Artery Clamp
Cooley Renal Artery clamp is ideally suited for use in cardiothoracic surgeries. The slightly curved shanks and angled jaws make this clamp perfect for its ideal use which is as a renal clamp to fully or partially cause occlusion of the renal vessels. These jaws are atraumatic thus reducing injury and stress to the vessel walls while still remaining firmly in their affixed location. This instrument is available in three sizes: 7.25", 7.5" and 10.75" to accommodate a number of different surgical approaches and surgeon preferences.
Cooley Anastomosis Clamp
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
Cooley Cardiovascular Clamp
Cooley Cardiovascular Clamp
2" (5.1 cm) curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is an ideal tool for use in cardiothoracic surgical procedures that require clamping of vessels to prevent excessive bleeding. This instrument is designed with two inch curved jaws that allow for stable closure of vessel while maintaining gentle enough pressure on the vessel wall to prevent damage or tearing. Additionally, this clamp features a ratcheting mechanisms to keep the clamp locked in place during surgery.
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp is a specialized piece of equipment designed for optimal use in cardiothoracic surgical procedures. This clamp is designed for use as a renal clamp to block or reduce blood flow through the renal vessels going to and from the kidney. To accommodate the positioning of these vessels this instrument comes with a significant angle to the jaws making access to the renal vasculature easier. This instrument is available angled either to the left or the right and also comes in either small or large jaws to accommodate a number of different patients sizes.
Cooley Occlusion Clamp
Cooley Occlusion Clamp
curved jaws, jaws 3.6 cm long
Cooley Occlusion Clamp is designed for use in cardiothoracic surgical procedures. This clamp can be used to clamp vessels to reduce or stop blood flow to prevent the patient from losing an excessive amount of blood. The jaws allow for firm grasp of the vessels but with reduced risk of crushing or bruising to the vessel wall. Additionally, this clamp features curved shanks and jaws giving them a contour more suitable for use in vascular surgical procedures. This instrument is available in two different lengths to accommodate different vessel sizes and positions.
Reviews
There are no reviews yet.